Using RFID with Loftware Label Manager
Block #
This shows the block type or block number. The number and type of blocks available depend on the
selected Tag Type, as shown in the table below.
UHF Gen 1
UHF Class 1
Gen 2
HF
Tags
Class
1
Class
0+
UCODE EPC
1.19
ISO 18000-
6B
PC
KC
AP
KP
EPC
USR
# X
to n
Block # 0 Block # 0
# X to
n
Tag
Type
Description
PC
Used for a 64-bit and 96-bit Class 1 Gen 1 tags, this is the Pass Code, a 1-byte value used
to deactivate the tag and render it unresponsive to reader commands.
The Pass Code is required to lock the EPC block and/or to enable Lock Tag After Writing.
The Lock setting of the PC block is disabled.
KC Used for a Class 0+ tag, this is the Kill Code, a 3-byte value that deactivates the tag.
AP
Used for a Class 1 Gen 2 tag, this is the Access Password, a 4-byte value that allows access
commands to be executed, including writing to locked blocks, and sets the tag in secure
state. To lock the EPC or the KP block of a Class 1 Gen 2 tag, AP must first be set.
KP
For a Class 1 Gen 2 tag, this is the Kill Password, a 4-byte value that will be used to
deactivate the tag.
EPC Used to select an EPC or DOD encoding from the Data Source column.
USR
For a Class 0+ tag, this block can be used for 13 bytes of user data. For a C1G2 tag, this
block can be used for 32 bytes of user data.
For the HF tag type, this column lists the configurable block number (from X to n).
Data Source
Setting Description
Unused No data will be sent to this block.
Fixed When selected, data for this block can be directly entered in the Data column.
Field
When selected, an existing field on the label can be chosen from a drop down list in the
Data column. The list is limited to variable text and barcode fields for labels. For tags,
this is limited to variable text fields.